Rosemount 848T Manual de usuario

Busca en linea o descarga Manual de usuario para No Rosemount 848T. Rosemount 848T FOUNDATION™ fieldbus High Density Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Quick Start Guide
00825-0100-4697, Rev EB
January 2015
Rosemount 848T FOUNDATION
fieldbus
High Density Temperature Transmitter
Device Revision 8 - Requires New DD/CFF Revision
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - fieldbus

Quick Start Guide00825-0100-4697, Rev EBJanuary 2015Rosemount 848T FOUNDATION™ fieldbus High Density Temperature TransmitterDevice Revision 8 - Requir

Pagina 2

January 201510Quick Start GuideStep 3: Verify the tagThe 848T has a removable commissioning tag that contains both the Device ID (the unique code that

Pagina 3 - Step 1: Mount the transmitter

Quick Start Guide11January 2015Analog input (AI) function blocksThe AI block processes field device measurements and makes the outputs available to ot

Pagina 4 - 2-in. screws

January 201512Quick Start GuideMultiple analog input (MAI) function blockThe MAI block processes up to eight field device measurements and makes the o

Pagina 5 - Step 2: Wire and apply power

Quick Start Guide13January 2015Product CertificationsEuropean Directive InformationA copy of the EC Declaration of Conformity can be found at the end

Pagina 6 - 11 1 1222 23333

January 201514Quick Start GuideN5 Nonincendive and Dust-Ignitionproof Certificate: 3011568 Standards: FM Class 3600:1998, FM Class 3611:2004, FM Clas

Pagina 7 - Wiring analog inputs

Quick Start Guide15January 2015I6 CSA Intrinsically Safe and Division 2Certificate: 1261865Standards: CAN/CSA C22.2 No. 0-M91 (R2001), CAN/CSA C22.2 N

Pagina 8 - Grounded thermocouple inputs

January 201516Quick Start GuideIA ATEX FISCO Intrinsic SafetyCertificate: Baseefa09ATEX0093XStandards: EN 60079-0:2012, EN60079-11:2012Markings:

Pagina 9 - Analog device inputs

Quick Start Guide17January 2015NC ATEX Type n (without enclosure)Certificate: Baseefa09ATEX0094UStandards: EN 60079-0:2006, EN60079-15:2005Markings:

Pagina 10 - Step 3: Verify the tag

January 201518Quick Start GuideInternationalI7 IECEx Intrinsic SafetyCertificate: IECEx BAS 09.0030XStandards: IEC 60079-0:2011, IEC60079-11:2011Marki

Pagina 11 - January 2015

Quick Start Guide19January 20152. The electrical circuit is connected directly to earth; this must be taken into account when installing the apparatus

Pagina 12

January 20152Quick Start GuideNOTICEThis guide provides basic guidelines for the Rosemount 848T. It does not provide instructions for detailed configu

Pagina 13 - Product Certifications

January 201520Quick Start GuideIB INMETRO Intrinsic SafetyCertificate: NCC 12.1156XStandards: ABNT NBR IEC 60079-0:2008 Versão corrigida 2011, ABNT NB

Pagina 14

Quick Start Guide21January 2015ChinaI3 NEPSI Intrinsic SafetyCertificate: GYJ111365XStandards: GB3836.1-2000, GB3836.4-2000Markings: Ex ia IIC T4Speci

Pagina 15

January 201522Quick Start Guide9. During installation, use and maintenance of this product, observe following standards:GB3836.13-1997 “Electrical app

Pagina 16

Quick Start Guide23January 2015JapanI4 TIIS FISCO Intrinsic Safety (ia)Certificate: TC19713Markings: IIC T4H4 TIIS FISCO Intrinsic Safety (ib)Certific

Pagina 17

January 201524Quick Start GuideAdditional CertificationsSBS American Bureau of Shipping (ABS) Type ApprovalCertificate: 011-HS771994C-1-PDAABS Rules:

Pagina 18 - International

Quick Start Guide25January 2015Figure 10. EC Declaration of Conformity for 848T Temperature Transmitter

Pagina 19

January 201526Quick Start Guide

Pagina 20

Quick Start Guide27January 2015

Pagina 21

Quick Start Guide00825-0100-4697, Rev EBJanuary 2015Rosemount World HeadquartersEmerson Process Management 6021 Innovation BlvdShakopee, MN 55379, USA

Pagina 22

Quick Start Guide3January 2015Step 1: Mount the transmitterMount to a DIN rail without a junction box1. Pull up the DIN rail mounting clip located on

Pagina 23 - Conduit Plugs and Adapters

January 20154Quick Start GuideFigure 3. Stainless Steel Junction BoxMounting to a 2-in. pipe standUse the optional mounting bracket (option code B6)

Pagina 24 - Additional Certifications

Quick Start Guide5January 2015Figure 6. Mounted on a Vertical PipeStep 2: Wire and apply powerPower is polarity insensitive, allowing the user to con

Pagina 25

January 20156Quick Start GuideFigure 7. Wiring ConnectionsSensor wiring and power supply Compatible with eight independently configurable channels i

Pagina 26

Quick Start Guide7January 2015Wiring analog inputsFigure 9. 848T Analog Input Wiring DiagramA. Analog Input ConnectorsB. Analog TransmittersC. Power

Pagina 27

January 20158Quick Start GuideGround the transmitter Proper ground is crucial to reliable temperature readings.Ungrounded thermocouple, mV, and RTD/Oh

Pagina 28 - 00825-0100-4697

Quick Start Guide9January 20154. Ground FOUNDATION fieldbus signal wiring shield at the power supply end.Analog device inputs1. Ground analog signal w

Comentarios a estos manuales

Sin comentarios