Reference Manual
00809-0100-4697, Rev GA
Section 2: Installation
November 2014
5Installation
Section 2 Installation
Safety messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
Tagging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
2.1 Safety messages
Instructions and procedures in this section may require special precautions to ensure the safety
of the personnel performing the operations. Information that potentially raises safety issues is
indicated by a warning symbol ( ). Refer to the following safety messages before performing
an operation preceded by this symbol.
2.1.1 Warnings
2.2 Mounting
The 848T is always mounted remote from the sensor assembly. There are three mounting
configurations.
To a DIN rail without an enclosure
To a panel with an enclosure
To a 2-in pipe stand with an enclosure using a pipe mounting kit
Failure to follow these installation guidelines could result in death or serious injury.
Make sure only qualified personnel perform the installation.
Process leaks could result in death or serious injury.
Do not remove the thermowell while in operation. Removing while in operation may
cause process fluid leaks.
Install and tighten thermowells and sensors before applying pressure, or process
leakage may result.
Electrical shock could cause death or serious injury.
If the sensor is installed in a high voltage environment and a fault condition or
installation error occurs, high voltage may be present on transmitter leads and
terminals.
Use extreme caution when making contact with the leads and terminals.